<LOGO>
FM Transmitter Measurement Report
Created: 2025-07-24 01-13-59
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
94.70 MHz 5/5, 53 dBuV SANDELS
Pilot RDS Phase Difference
6.1 kHz 5.5 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
14 kHz 73 kHz 11073 22,1710
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
4,7 dBr 5,50 dBr 6,2 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"SANDELS " 61F1 9 (Varied) 1 0 1 13 --:--
RT
-
AF EON
92.0, 94.7, 106.4, 107.5 MHz -
FM Scope Max at: 73 kHz MIN: 14 kHz % above 76 kHz: 22,1710 Acquired: 2025/07/24 1.12.56 Total samples: 11073 Equivalent time: 0:09:13 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 200 400 600
FM Scope MAX: 6,2 dBr MIN: 4,7 dBr AVE: 5,50 dBr % above 12,2 dBr: 0,0 Last value: 6,2 dBr (2025/07/24 1.12.55) 01.00 01.02 01.04 01.06 01.08 01.10 01.12 0 2 4 6 Pm [dBr]